৳0.00 | Brand: CONTEC |
| Model: TLC9803 |
| Brief Introduction |
| TLC9803 Dynamic ECG Systems adapts our company’s3-lead scheme, is able to continually record ECG waves for 24 hours, and analyze waves using PC software. It is applicable in the medical establishment of the hospital and community. |
| Recorder Features |
| The recorder can work stable, reliable and durable with advanced design and technology. |
| Provide anti-jamming and aseismic capacity. |
| Small OLED-screen volume. 160* 128 is the resolution. |
| Waveform preview, record review, and event marking features are given. |
| Precise recording of the starting moment of the sampled information due to the actual clock itself. |
| Avoid harm due to repeated insertion and removal by using the built-in TF card for information storage. |
| Maximum capacity can be 2 GB, so no compression can save the original data perfectly. |
| Using the USB 2.0 interface, the average review time of a single case may be less than 40 seconds. |
| Record inexpensive waveform details by designing high precision and frequency of sampling. |
| Record the pacemaker status by a greater rate of sampling. |
| The Features of Software |
| Rapid and accurate system of analysis. |
| In order to find accurate, 3-lead synchro analysis, QRS search can be accurate and without distortion. |
| There are over 10 templates, such as atrial premature beat module, ventricular premature beat module, lengthy interval module, atrial flutter module, atrial fibrillation module, etc., and multiple user-defined templates could almost recognize any type of pathological waveform. |
| Flexible selection channel analysis function, any channel can be selected as the channel primarily analyzed. |
| Flexible atrial fibrillation analysis to enable doctors to use full, segmented automatic, manual atrial fibrillation analysis to make the analysis faster and more accurate. |
| Many modules for pacing were added. |
| Fast review analysis function can be a single lead check or an electrocardiogram of all leads. |
| Analysis of short-range5-minute hearing rate variability and long-range1-hourand 24-hour heart rate variability analysis. |
| One-stop printing, report printing is convenient and fast. |
| Perfect case management functionality. |
| Advanced analysis of the ST segment and total load of myocardial ischemia, may allow the doctor to make a comprehensive assessment of myocardial ischemia for an ST abnormal analysis according to the whole and event. |
| Analysis of the single “Sleep breath pause syndrome analysis” may predict the risk of sleep breath pause. |
| ” Analysis of HRT in patients with myocardial infarction can predict the risk of death. |
| Analysis of “T Wave Alternation” is an important index for predicting malignant arrhythmia and sudden cardiac death. |
| Standard |
| Channel number: 3 channels |
| Sampling accuracy:12Bit |
| Record time: 24 h |
| Power: 2 AA batteries |
| Interface: USB2.0 |
| Scale voltage: 1mV±5 percent |
| Standard sensitivity: 10mm / mV±5 percent |
| Noise level:30?V |
| CMRR: 60dB |
| Characteristics of low frequency: constant time?Duration of polarization voltage: ±300mV DC polarization voltage, sensitivity shift?±10 percent |
| Minimum signal of measurement: 50 μV p-p |
| Safety form of product: Type B (internally driven) |
| Accessories |
| 3-lead ECG lead wires (1 set) |
| 1 bag(20 per bag) |
| USB information line(1) |
| Disk(1) |
| Bag(1) |
| User manual(1) |
| Physical characteristic |
| Dimension:111mm(L) * 60mm(W) *25mm(H) |
| Weight:About 105g(without battery) |
| Certificate: CE FDA |